Shopping Cart

No products in the cart.

ASTM-E839 2005

$44.96

E839-05 Standard Test Methods for Sheathed Thermocouples and Sheathed Thermocouple Material

Published By Publication Date Number of Pages
ASTM 2005 15
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 These are test methods for sheathed thermocouple material and assemblies.

1.2 The tests are intended to ensure quality control and to evaluate the suitability of sheathed thermocouple material or assemblies for specific applications. Some alternative test methods to obtain the same information are given, since in a given situation an alternative test method may be more practical. Service conditions are widely variable and so it is unlikely that all the tests described will be appropriate for a given thermocouple application. A brief statement is made following each test description to indicate when it might be used.

1.3 The tests described herein include test methods to measure the following properties of sheathed thermocouple material and assemblies.

1.3.1 Insulation PropertiesCompaction-absorption method and tension method.

Thickness.

Resistance-room temperature and elevated temperature.

1.3.2 Sheath Properties Integrity-water test (two test methods) and mass spectrometer.

Dimensions-length, diameter, and roundness.

Wall thickness.

Surface-gross visual, finish, defect detection by dye penetrant, and cold-lap detection by tension test.

Metallurgical structure.

Ductility-bend test and tension test.

1.3.3 Thermoelement PropertiesCalibration.

Homogeneity.

Drift.

Thermoelement diameter, roundness, and surface appearance.

Thermoelement spacing.

Thermoelement ductility.

Metallurgical structure.

1.3.4 Thermocouple Assembly PropertiesDimensions-length, diameter, and roundness.

Surface-gross visual, finish, reference end seal, and defect detection by dye penetrant.

Electrical-continuity, loop resistance, and connector polarity.

Radiographic inspection.

Thermoelement diameter.

Thermal response time.

Thermal cycle.

PDF Catalog

PDF Pages PDF Title
1 Scope
2 Referenced Documents
Terminology
Summary of Test Methods
3 Significance and Use
General Requirements
Insulation Properties
4 FIG. 1
FIG. 2
FIG. 3
5 FIG. 4
FIG. 5
6 Sheath Properties
7 FIG. 6
8 Thermoelement Properties
FIG. 7
9 Thermocouple Assembly Properties
11 FIG. 8
12 Report
FIG. 9
13 Precision and Bias
Keywords
X1. EXAMPLES OF SPECIFICATIONS, TOLERANCES, AND ACCEPTANCE CRITERIA
X1.1 Sheath, Thermoelement, and Insulation Thickness Examples
X1.2 Insulation Resistance
X1.3 Sheath Roundness and Wall Thickness for Various Sheath Diameters
X1.4 Bend Test and Tension Test Acceptance Criteria (Examples)
X1.5 Upper Temperature Limit for Various Sheath Diameters
TABLE X1.1
TABLE X1.2
TABLE X1.3
TABLE X1.4
14 X1.6 Tolerances on Initial Values of EMF versus Temperature
X1.7 Radiographic Penetrameter and Shim Thickness
X1.8 Bend and Tension Test
X1.9 Evaluation of Sheath to Thermoelement Locking
TABLE X1.5
TABLE X1.6
TABLE X1.7
TABLE X1.8
ASTM-E839 2005
$44.96