E1507-98(2003) Standard Guide for Describing and Specifying the Spectrometer of an Optical Emission Direct-Reading Instrument
Published By | Publication Date | Number of Pages |
ASTM | 2003 | 17 |
ASTM E1507-98-Reapproved2003
Withdrawn Standard: Standard Guide for Describing and Specifying the Spectrometer of an Optical Emission Direct-Reading Instrument (Withdrawn 2003)
ASTM E1507
Scope
1.1 This guide covers features of a spectrometer or polychromator used for optical emission, direct-reading, spectrochemical analysis. A polychromator in this sense consists of a spectrometer with an extended and fixed wavelength range and an array of fixed exit slits to isolate the spectral lines of the elements to be measured.
1.1.1 This guide does not apply to direct-reading systems that employ echelle spectrometers and vidicon or other detectors where the design parameters are quite different.
1.2 This guide covers only the optical portion of the instrument, from excitation stand to photomultipliers.
1.2.1 Only general statements are made about source units.
1.2.2 Photomultipliers are included to the extent that they are mounted within the spectrometer to convert optical intensities to electrical signals, and establish the instrumental precision of each channel as a light measuring device. Readout systems are not included.
1.3 It is not the purpose of this guide to establish binding specifications or tolerances, but rather, to call attention to important parameters that manufacturers should include in their literature, to provide methods for measuring those parameters, and to assign values that are indicative of acceptably good performance. Because of the great variety of demands imposed by spectrochemical techniques, rigid performance criteria are not feasible.
1.4 The values stated in SI units are to be regarded as the standard.
1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
astigmatism; detection; diffraction grating; direct-reading spectrometer; line interference; optical emission spectrometer (OES); optical working resolution; radiation throughput; scattered light
ICS Code
ICS Number Code 17.180.30 (Optical measuring instruments)
DOI: 10.1520/E1507-98R03
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope |
2 | Referenced Documents Terminology Significance and Use Fundamental Spectrochemical Objectives |
3 | Parameters of Spectrometers and Associated Components That Affect Spectrochemical Performance |
5 | FIG. 1 |
6 | Measuring Specified Polychromator Parameters |
7 | FIG. 2 TABLE 1 |
8 | FIG. 3 |
9 | Describing the Spectrometer in Analytical Methods Keywords X1. EFFECTS OF VARYING PARAMETERS ON WORKING RESOLUTION AND THROUGHPUT X1.1 X1.2 TABLE X1.1 |
10 | X1.3 X1.4 FIG. X1.1 TABLE X1.2 |
11 | X2. RECOMMENDED SPECTRAL LINES AND CONCENTRATION RANGES FOR MEASURING WORKING RESOLUTION X2.1 X2.2 |
12 | X3. PHOTOGRAPHIC SPEED VERSUS PHOTOELECTRIC THROUGHPUT X3.1 X3.2 TABLE X2.1 |
13 | X3.3 FIG. X3.1 |
14 | FIG. X3.2 FIG. X3.3 TABLE X3.1 FIG. X3.4 |
15 | X3.4 FIG. X3.5 |
16 | REFERENCES TABLE X3.2 |