Shopping Cart

No products in the cart.

ASTM-D7619:2010 Edition

$40.63

D7619-10 Standard Test Method for Sizing and Counting Particles in Light and Middle Distillate Fuels, by Automatic Particle Counter

Published By Publication Date Number of Pages
ASTM 2010 9
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

ASTM D7619-10

Historical Standard: Standard Test Method for Sizing and Counting Particles in Light and Middle Distillate Fuels, by Automatic Particle Counter

ASTM D7619

Scope

1.1 This test method uses a specific automatic particle counter (APC) to count and measure the size of dispersed dirt particles, water droplets and other particles, in light and middle distillate fuel, and bio fuels such as biodiesel and biodiesel blends, in the overall range from 4 Āµm(c) to 100 Āµm(c) and in the size bands ā‰„4 Āµm(c), ā‰„6 Āµm(c), and ā‰„14 Āµm(c).

Note 1ā€”ASTM specification fuels falling within the scope of this test method include Specifications: D975 grades 1D and 2D, D3699, D4814 (see 14.1.1.1), D6751, D6985, D7467 and distillate grades of D396 and D2880.

Note 2ā€”For the purposes of this test method, water droplets are counted as particles, and agglomerated particles are detected and counted as a single larger particle. Dirt includes biological particles. Although the projected area of a particle is measured, this is expressed as the diameter of a sphere for the purposes of this test method.

Note 3ā€”The notation (c), used with particle sizes, is used to denote that the apparatus has been calibrated in accordance with ISO 11171. Strictly this only applies to particles up to 50 Āµm.

Note 4ā€”This test method may be used for particle sizes bands up to 100 Āµm(c), however the precision has only been determined for the size bands ā‰„4 Āµm(c), ā‰„6 Āµm(c), and ā‰„14 Āµm(c).

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

automatic particle counting; automotive diesel; biodiesel; fuel cleanliness; gas oil; gasoline; kerosine; marine diesel; Light distillates; Middle distillate fuels; Automatic particle counters; Distillate fuels

ICS Code

ICS Number Code 75.160.20 (Liquid fuels)

DOI: 10.1520/D7619-10

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
2 Terminology
Summary of Test Method
Significance and Use
Apparatus
3 Reagents and Materials
Sampling
Preparation of Apparatus
Test Specimen Preparation
4 Procedure
Report
TABLE 1
5 Precision and Bias
Keywords
TABLE 2
6 A1. AUTOMATIC PARTICLE COUNTING APPARATUS (APC)
A1.1 General
A1.2 Automatic Changeover Valve
A1.3 Double Pump
A1.4 Laser
A1.5 Test Specimen Delivery Tube Assembly
A1.6 Calibration Software
A1.7 Pre-Measurement Checks
FIG. A1.1
7 X1. TABULAR AND GRAPHICAL REPRESENTATION OF PRECISION
TABLE X1.1
FIG. X1.1
TABLE X1.2
8 FIG. X1.2
TABLE X1.3
9 FIG. X1.3
ASTM-D7619
$40.63