Scope

1.1 This test method utilizes an oxygen-pressured vessel to evaluate the oxidation stability of new and in-service turbine oils having the same composition (base stock and additives) in the presence of water and a copper catalyst coil at 150°C.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.2.1 ExceptionOther units are provided in parentheses (psi, grams, and inches), because they are either the industry accepted standard or the apparatus is built according the figures in this standard, or both.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 6.2, 6.4, 6.5, 6.6, and 6.10.

Keywords

dry block bath; induction period; liquid bath; oxidation stability; rotating pressure vessel; steam turbine oils; RBOT (rotating bomb oxidation test); Bomb methods; Gas turbine fuel oils; Oxidative stability; Oxygen bomb method–oxidation stability

ICS Code

ICS Number Code 75.100 (Lubricants, industrial oils and related products)

DOI: 10.1520/D2272-09

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Summary of Test Method
Significance and Use
Apparatus
2 Reagents and Materials
FIG. 1
FIG. 2
3 Sampling
Preparation of Apparatus
Procedure
4 Quality Control Monitoring
Report
FIG. 3
5 Precision and Bias
Apparatus
Reagents and Materials
Sampling
6 Preparation of Apparatus
Procedure
7 Quality Control Monitoring
Report
Precision and Bias
Keywords
8 A1. APPARATUS FOR ROTARY PRESSURE VESSEL OXIDATION TEST
A1.1
A1.2
A1.3
A1.4
A1.5
A1.6
9 FIG. A1.1
10 FIG. A1.2
11 FIG. A1.3
12 FIG. A1.4
13 FIG. A1.5
FIG. A1.6
14 FIG. A1.7
15 A2. APPARATUS FOR ROTARY PRESSURE VESSEL OXIDATION TEST—METAL BLOCK BATH
A2.1 Pressure Chamber Access
A2.2 Pressure Chamber Lid
A2.3 Knurled Lid Nuts
A2.4 Magnetic Cup
A2.5 Glass Sample Beaker
A2.6 Beaker Cover
A2.7 Copper Coil Catalyst
A2.8 Spring Clip
A2.9 Cup and Beaker Removal Tongs
A2.10 Lid Removal Tool
FIG. A1.8
16 A2.11 Oxygen (O2) Fill Valve
A2.12 Oxygen (O2) Vent Valve
A2.13 Anti-Friction Band
A2.14 Lid Alignment Wire
A2.15 PTFE Lid Cover
FIG. A2.1
17 FIG. A2.2
FIG. A2.3
18 FIG. A2.4
FIG. A2.5
19 FIG. A2.6
ASTM-D2272 2009
$44.96