ASTM-C657 2003
$40.63
C657-93(2003) Standard Test Method for D-C Volume Resistively of Glass
Published By | Publication Date | Number of Pages |
ASTM | 2003 | 5 |
ASTM C657-93-Reapproved2003
Historical Standard: Standard Test Method for D-C Volume Resistively of Glass
ASTM C657
Scope
1.1 This test method covers the determination of the dc volume resistively of a smooth, preferably polished, glass by measuring the resistance to passage of a small amount of direct current through the glass at a voltage high enough to assure adequate sensitivity. This current must be measured under steady-state conditions that is neither a charging current nor a space-charge, buildup polarization current.
1.2 This test method is intended for the determination of sensitivities less than 1016 Ω ·cm in the temperature range from 25°C to the annealing point of the glass.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 5.
Keywords
temperature; copper; copper-copper oxide; voltage; glass
ICS Code
ICS Number Code 81.040.10 (Raw materials and raw glass)
DOI: 10.1520/C0657-93R03
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Summary of Test Method Significance and Use Cautions Apparatus |
2 | Test Specimen FIG. 1 |
3 | Procedure FIG. 2 FIG. 3 |
4 | Calculations Report FIG. 4 |
5 | Precision and Bias A1. FACTORS AFFECTING RESISTANCE MEASUREMENTS A1.1 FIG. 5 |