ASTM-B699 2015
$40.63
B699-86(2015) Standard Specification for Coatings of Cadmium Vacuum-Deposited on Iron and Steel
Published By | Publication Date | Number of Pages |
ASTM | 2015 | 6 |
ASTM B699-86-Reapproved2015
Historical Standard: Standard Specification for Coatings of Cadmium Vacuum-Deposited on Iron and Steel
ASTM B699
Scope
1.1 This specification covers the requirements for a cadmium coating vacuum-deposited on iron and steel basis metals. The coating is especially beneficial to those ferrous metals, heat treated to 46HRC and higher or having an ultimate tensile strength greater than 1500 MPa, wherein protection against corrosion and appearance are important (see Appendix X1).
1.2 Vacuum-deposited production items are normally free of hydrogen embrittlement, a danger when using electroplating processes for deposition. Vacuum deposition can handle large high-strength parts that cannot be conveniently mechanically plated in the rotating barrels.
1.3 The coating is provided in various thicknesses up to and including 12 Ī¼m (3.1) either in the as-deposited condition or with a supplementary finish (3.2).
1.4 āThe following precautionary caveat pertains only to the test methods portion, Section 9, of this specification: This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
cadmium coatings, vacuum deposited; vacuum deposited coatings, cadmium;
ICS Code
ICS Number Code 25.220.40 (Metallic coatings)
DOI: 10.1520/B0699-86R15