Shopping Cart

No products in the cart.

ASME CSD 1 2021

$98.04

ASME CSD-1 – 2021 Controls and Safety Devices for Automatically Fired Boilers

Published By Publication Date Number of Pages
ASME 2021 70
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The rules of this Standard cover requirements for the assembly, installation, maintenance, and operation of controls and safety devices on automatically operated boilers directly fired with gas, oil, gas-oil, or electricity, having fuel input ratings under 12,500,000 Btu/hr.

PDF Catalog

PDF Pages PDF Title
4 CONTENTS
6 FOREWORD
7 ASME CSDAFB COMMITTEE ROSTER
8 CORRESPONDENCE WITH THE CSDAFB COMMITTEE
10 ASME CSD-1–2021 SUMMARY OF CHANGES
12 Part CG General
CG-100 GENERAL REQUIREMENTS
CG-110 Scope
CG-120 Service Limitations
CG-130 Exclusions
CG-140 Acceptance of Other Listings
CG-150 Jurisdictional Adoption of ASME CSD-1
CG-160 Metric (SI) Units
13 CG-200 GENERAL PROVISIONS
CG-210 General
CG-220 Installation
CG-230 Observation Ports
CG-240 Guarding
CG-250 Annunciator Systems
CG-260 Combustion Air
CG-300 MATERIAL REQUIREMENTS
CG-310 Components
CG-400 TESTING AND MAINTENANCE
CG-410 Cleaning
CG-420 Testing
CG-430 Maintenance
14 CG-440 Operational Testing
CG-500 CERTIFICATION AND REPORTING
CG-510 Certification and Reporting
CG-600 OPERATION
CG-610 Lockout
CG-700 DEFINITIONS
19 Figures
Figure CG-700-1 Sediment Trap
21 Part CM Testing and Maintenance
CM-100 PERIODIC TESTING AND MAINTENANCE
CM-110 General
CM-120 Familiarity With Equipment and Procedures
CM-130 Periodic Maintenance and Testing
22 Part CE Electrical
CE-100 ELECTRICAL REQUIREMENTS
CE-110 General
CE-120 Overcurrent Protection
23 CE-130 Motors
CE-140 Ignition System
CE-150 Wiring
CE-160 Bonding and Grounding
CE-170 Annunciation, Status, and Control Wiring to Primary Safety Control Systems
24 Part CW Steam and Waterside Control
CW-100 AUTOMATIC LOW-WATER FUEL CUTOFF AND/OR COMBINED WATER FEEDING DEVICE
CW-110 General Requirements for Water Level Controls for All Boilers
CW-120 Requirements for Water Level Controls for Low-Pressure Steam Boilers
25 CW-130 Requirements for Water Level Controls for Hot Water Heating Boilers
CW-140 Requirements for Water Level Controls for High-Pressure Steam Boilers
26 CW-150 Requirements for Operating and Safety Controls for Electrically Heated Boilers
CW-200 AUTOMATIC FUEL CUTOFF FOR FORCED CIRCULATION BOILERS
CW-210 Requirements for Flow or Temperature Sensing Devices for Forced Circulation Boilers
CW-300 PRESSURE CONTROLS
CW-310 Requirements for Pressure Controls for Steam Boilers
27 CW-400 TEMPERATURE CONTROLS
CW-410 Requirements for Temperature Controls for Hot Water Boilers
28 CW-500 SAFETY AND SAFETY RELIEF VALVES
CW-510 Requirements for Steam and Hot Water Heating Boilers
CW-520 Requirements of Hot Water Supply Boilers
CW-600 MODULAR BOILERS
CW-610 Water Level Controls for Modular Steam Heating Boilers
CW-620 Pressure Controls for Modular Steam Heating Boilers
CW-630 Water Level Controls for Modular Hot Water Boilers
CW-640 Temperature Controls for Modular Hot Water Heating Boilers
CW-700 VACUUM BOILERS
CW-710 Requirements for Vacuum Boilers
30 Part CF Combustion Side Control
CF-100 GAS-FIRED BOILER UNITS, EQUIPMENT
CF-110 Burner Assemblies and Boiler Units
CF-120 Fuel Train
CF-130 Filters or Strainers
CF-140 Sediment Traps and Drips
CF-150 Manually Operated Gas Shutoff Valves
31 Tables
Table CF-110-1 400,000 Btu/hr (117 kW) and Smaller (Gas — Natural Draft)
32 Table CF-110-2 400,000 Btu/hr (117 kW) and Smaller (Power Gas Burners, Mechanical Draft Atmospheric Gas Burners, Pulse Combustion Systems), 3 gph (11.4 L/h) [Approximately 400,000 Btu/hr (117 kW)] and Smaller (Oil)
33 CF-160 Gas-Pressure Regulators
34 Table CF-162-1 Safety Controls for Automatically Fired Units: Power Gas Burners, Mechanical Draft Atmospheric Gas Burners, and Pulse Combustion Systems
36 Table CF-162-2 Safety Controls for Automatically Fired Units: Atmospheric Gas Burners — Natural Draft
37 CF-170 Control Valves
CF-180 Safety Shutoff Valves
38 CF-190 Vent Lines, Bleed Lines, Gas-Pressure Relief Lines, Vent Valve Lines, and Feedback Lines for Fuel Train Components
39 CF-200 GAS-FIRED BOILER UNITS, PURGING
CF-210 Preignition Purging
40 CF-220 Control
CF-300 GAS-FIRED BOILER UNITS, SAFETY CONTROLS
CF-310 Primary Safety Control
CF-320 Automatic Ignition Devices
CF-330 Action on Flame Failure
41 CF-400 OIL-FIRED BOILER UNITS, EQUIPMENT
CF-410 Burner Assemblies
CF-420 Fuel Train
CF-430 Filters or Strainers
CF-440 Relief Valves
CF-450 Pressure and Temperature Switches
CF-460 Safety Shutoff Valves
42 CF-470 Oil-Fired Boiler Units, Purging
CF-480 Combustion Air Proving
CF-500 OIL-FIRED BOILER UNITS, SAFETY CONTROLS
CF-510 Primary Safety Control
CF-520 Automatic Ignition Devices
CF-530 Action on Flame Failure
CF-540 Automatic Stack Dampers
43 Table CF-460-1 Safety Controls for Automatically Fired Units: Oil-Fired Burners
44 CF-600 LOW FIRE START, GAS- OR OIL-FIRED BOILER UNITS
CF-610 Low Fire Start
CF-700 COMBINATION GAS- AND OIL-FIRED UNITS
CF-710 Burner Assemblies
CF-800 ELECTRICALLY HEATED BOILERS
CF-810 General
CF-900 COMBUSTION SIDE CONTROLS FOR MODULAR BOILERS
CF-910 Gas Modular Boilers
CF-920 Oil Modular Boilers
CF-930 Electric Modular Boilers
CF-1000 Requirements for the Use of Variable Frequency Drives (VFD)
CF-1010 VFD Used on Combustion Air Fan
46 NONMANDATORY APPENDICES
NONMANDATORY APPENDIX A COMPARISON OF THIS STANDARD AND ANSI Z21.13/CSA 4.9
47 Table B-1 Figure Index
NONMANDATORY APPENDIX B TYPICAL FUEL TRAINS
48 Figure B-1 Typical Gas Fuel Train With Pilot Ignition System and Atmospheric Burners [Greater Than 400,000 Btu/hr (117 kW) and Less Than or Equal to 2,500,000 Btu/hr (733 kW)]
49 Figure B-2 Typical Gas Fuel Train With Pilot Ignition System [Greater Than 400,000 Btu/hr (117 kW) and Less Than or Equal to 2,500,000 Btu/hr (733 kW)]
51 Figure B-3 Typical Gas Fuel Train With Direct Ignition System [Greater Than 400,000 Btu/hr (117 kW) and Less Than or Equal to 2,500,000 Btu/hr (733 kW)]
52 Figure B-4 Typical Gas Fuel Train With Pilot Ignition System [Greater Than 2,500,000 Btu/hr (733 kW) and Less Than or Equal to 5,000,000 Btu/hr (1 465 kW)]
54 Figure B-5 Typical Gas Fuel Train With Pilot Ignition System [Greater Than 5,000,000 Btu/hr (1 465 kW) and Less Than 12,500,000 Btu/hr (3 663 kW)]
55 Figure B-6 Typical Gas Fuel Train With Pilot Ignition System and Negative (Zero Governor) Main Manifold Gas Pressure [Greater Than 400,000 Btu/hr (117 kW) and Less Than 12,500,000 Btu/hr (3 663 kW)]
56 Figure B-7 Typical Gas Fuel Train With Direct Ignition System and Negative (Zero Governor) Main Manifold Gas Pressure [Greater Than 400,000 Btu/hr (117 kW) and Less Than 12,500,000 Btu/hr (3 663 kW)]
Figure B-8 Typical Oil Fuel Train
57 Figure B-9 Example for Sizing of Manifolded Lines
Figure B-10 Typical Gas Fuel Train Safety Shutoff Valve Arrangements for Multiple-Burner Boiler Units Complying With CF-180(b)
58 NONMANDATORY APPENDIX C MANUFACTURER’S/INSTALLING CONTRACTOR’S REPORT FOR ASME CSD-1
61 NONMANDATORY APPENDIX D RECOMMENDED PREVENTIVE MAINTENANCE SCHEDULE
D-1 INTRODUCTION
D-2 DAILY
D-3 WEEKLY
D-4 MONTHLY
D-5 SEMIANNUALLY
D-6 ANNUALLY
D-7 AS REQUIRED
63 Table D-1-1 Periodic Testing Recommended Checklist
66 NONMANDATORY APPENDIX E REFERENCES
67 NONMANDATORY APPENDIX F GUIDANCE FOR THE USE OF U.S. CUSTOMARY AND SI UNITS IN ASME CSD-1
F-1 USE OF UNITS IN EQUATIONS
F-2 GUIDELINES USED TO DEVELOP SI EQUIVALENTS
69 F-3 SOFT CONVERSION FACTORS
ASME CSD 1 2021