ASME BPVC VI 2007
$377.00
ASME BPVC – VI -2007 BPVC Section VI, Recommended Rules for the Care and Operation of Heating Boilers
Published By | Publication Date | Number of Pages |
ASME | 2007 |
None
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | LIST OF BPVC SECTIONS |
6 | CONTENTS 2. FIGURES |
7 | 3. FIGURES 3. TABLES |
8 | 5. FIGURES |
10 | FOREWORD |
12 | STATEMENTS OF POLICY |
14 | PERSONNEL |
26 | SUMMARY OF CHANGES |
28 | 1. GENERAL 1.01 SCOPE 1.02 USE OF ILLUSTRATIONS 1.03 MANUFACTURER’S INFORMATION 1.04 REFERENCE TO SECTION IV 1.05 GLOSSARY OF TERMS |
41 | 2. TYPES OF BOILERS 2.01 CLASSIFICATION 2.02 STEEL BOILERS 2.03 CAST IRON BOILERS 2.04 MODULAR BOILERS 2.05 VACUUM BOILERS |
42 | 2.02A-1 HORIZONTAL RETURN TUBE, BRICK-SET 2.02A-2 GAS FLOW PATTERNS OF SCOTCH-TYPE BOILERS |
43 | 2.02A-3 TYPE C FIREBOX BOILER 2.02A-4 THREE-PASS FIREBOX BOILER |
44 | 2.02A-5 LOCOMOTIVE FIREBOX BOILER 2.02A-6 VERTICAL FIRETUBE BOILER |
45 | 2.03A HORIZONTAL SECTIONAL CAST IRON BOILER 2.03B VERTICAL SECTIONAL CAST IRON BOILER 2.04A MODULES CONNECTED WITH PARALLEL PIPING 2.04B MODULES CONNECTED WITH PRIMARY-SECONDARY PIPING |
46 | 3. ACCESSORIES AND INSTALLATION 3.01 SAFETY AND SAFETY RELIEF VALVES 3.02 LOW- WATER FUEL CUTOFFS AND WATER FEEDERS 3.03 TRAPS 3.04 AIR ELIMINATORS 3.01 OFFICIAL SYMBOL |
47 | 3.05 CONDENSATE RETURN PUMPS AND RETURN LOOP 3.06 VACUUM RETURN PUMP 3.07 CIRCULATORS (CIRCULATING PUMPS) 3.08 EXPANSION TANK 3.01A SAFETY VALVE |
48 | 3.01B SAFETY RELIEF VALVE 3.02A FLOAT TYPE LOW-WATER CUTOFF |
49 | 3.02B ELECTRIC PROBE TYPE LOW-WATER CONTROL |
50 | 3.09 OIL PREHEATERS 3.10 FUEL OIL STORAGE AND SUPPLY SYSTEMS 3.11 PRESSURE GAGE 3.03-1 THERMOSTATIC TRAP 3.03-2 FLOAT TRAP 3.03-3 FLOAT AND THERMOSTATIC TRAP 3.03-4 BUCKET TRAP WITH TRAP CLOSED |
51 | 3.20 PRESSURE RELIEVING VALVE REQUIREMENTS |
52 | 3.05 TYPICAL RETURN LOOP |
53 | 3.11 PRESSURE GAGES |
54 | 3.20 MINIMUM POUNDS OF STEAM PER HOUR PER SQUARE FOOT OF HEATING SURFACE (kg/h/m2) |
55 | 3.20H SAFETY RELIEF VALVE DISCHARGE PIPE |
56 | 3.21 STEAM GAGES 3.22 WATER GAGE GLASSES 3.23 WATER COLUMN AND WATER LEVEL CONTROL PIPES |
57 | 3.24 PRESSURE CONTROL 3.25 PRESSURE OR ALTITUDE GAGES 3.26 THERMOMETERS 3.27 TEMPERATURE CONTROL 3.28 AUTOMATIC LOW- WATER FUEL CUTOFF AND/ OR WATER FEEDING DEVICE (STEAM) |
58 | 3.29 LOW- WATER FUEL CUTOFF (HOT WATER) 3.30 PIPING |
59 | 3.31 PROVISIONS FOR THERMAL EXPANSION IN HOT WATER SYSTEMS 3.32 STOP VALVES |
60 | 3.30-1 SINGLE HOT WATER HEATING BOILER — ACCEPTABLE PIPING INSTALLATION |
61 | 3.30-2 HOT WATER HEATING BOILERS IN BATTERY — ACCEPTABLE PIPING INSTALLATION |
62 | 3.30-3 SINGLE STEAM BOILERS — ACCEPTABLE PIPING INSTALLATION |
63 | 3.30-4A STEAM BOILERS IN BATTERY — PUMPED RETURN — ACCEPTABLE PIPING INSTALLATION |
64 | 3.30-4B STEAM BOILERS IN BATTERY — GRAVITY RETURN — ACCEPTABLE PIPING INSTALLATION |
65 | 3.33 BOTTOM BLOWOFF AND DRAIN VALVES 3.34 OIL HEATERS 3.35 SHUTDOWN SWITCHES AND CIRCUIT BREAKERS 3.31C-1 EXPANSION TANK CAPACITIES FOR GRAVITY HOT WATER SYSTEMS 3.31C-2 EXPANSION TANK CAPACITIES FOR FORCED HOT WATER SYSTEMS 3.33 SIZE OF BOTTOM BLOWOFF PIPING, VALVES, AND COCKS |
66 | 3.36 MODULAR BOILERS 3.37 VACUUM BOILERS 3.38 STORAGE TANKS FOR HOT WATER SUPPLY SYSTEMS |
67 | 4. FUELS 4.01 GAS — NATURAL, MANUFACTURED, MIXED 4.02 LIQUEFIED PETROLEUM GAS (LPG) 4.03 FUEL OILS |
68 | 4.04 COAL 4.05 ELECTRICITY |
69 | 5. FUEL BURNING EQUIPMENT AND FUEL BURNING CONTROLS 5.01 GAS BURNING EQUIPMENT 5.02 OIL BURNING EQUIPMENT 5.01A ATMOSPHERIC GAS BURNER |
70 | 5.01C COMBINATION FUEL BURNERS 5.02A HIGH-PRESSURE ATOMIZING BURNER |
71 | 5.03 COAL BURNING EQUIPMENT 5.04 CONTROLS 5.02D HORIZONTAL ROTARY CUP FUEL OIL BURNER |
72 | 5.03-1 UNDERFEED SINGLE-RETORT STOKER 5.03-2 OVERTHROW RECIPROCATING PLATE-FEED TYPE SPREADER STOKER |
73 | 5.03-3 CHAIN GRATE STOKER WITH SECTION SHOWING LINKS |
75 | 6. BOILER ROOM FACILITIES 6.01 GENERAL 6.02 SAFETY 6.03 LIGHTING 6.04 VENTILATION 6.05 WATER AND DRAIN CONNECTIONS 6.06 FIRE PROTECTION 6.07 HOUSEKEEPING |
76 | 6.08 POSTING OF CERTIFICATES AND/ OR LICENSES 6.09 RECORDKEEPING, LOGS, ETC. |
77 | 7. OPERATION, MAINTENANCE, AND REPAIR — STEAM BOILERS 7.01 STARTING A NEW BOILER AND HEATING SYSTEM |
78 | 7.02 STARTING A BOILER AFTER LAYUP (SINGLE BOILER INSTALLATION) 7.03 CONDENSATION 7.04 CUTTING IN AN ADDITIONAL BOILER 7.05 OPERATION |
80 | 7.06 REMOVAL OF BOILER FROM SERVICE 7.07 MAINTENANCE |
82 | 7.08 BOILER REPAIRS 7.09 TESTS AND INSPECTIONS OF STEAM HEATING BOILERS |
86 | 8. OPERATION, MAINTENANCE, AND REPAIR — HOT WATER BOILERS AND HOT WATER HEATING BOILERS 8.01 STARTING A NEW BOILER AND HEATING SYSTEM 8.02 STARTING A BOILER AFTER LAYUP (SINGLE BOILER INSTALLATION) |
87 | 8.03 CONDENSATION 8.04 CUTTING IN AN ADDITIONAL BOILER 8.05 OPERATION |
88 | 8.06 REMOVAL OF BOILER FROM SERVICE 8.07 MAINTENANCE |
90 | 8.08 BOILER REPAIRS |
91 | 8.09 TESTS AND INSPECTIONS OF HOT WATER HEATING AND SUPPLY BOILERS |
94 | 9. WATER TREATMENT 9.01 SCOPE 9.02 CONSIDERATIONS 9.03 SERVICES OF WATER TREATMENT SPECIALISTS 9.04 CONFORMITY WITH LOCAL ORDINANCES 9.05 BOILER WATER TROUBLES 9.06 CHEMICALS USED |
95 | 9.07 FUNCTIONS OF CHEMICALS 9.08 TREATMENT ALTERNATIVES 9.09 BLOWDOWN |
96 | 9.10 FEEDERS 9.11 PROCEDURES 9.12 GLOSSARY OF WATER TREATMENT TERMS |
98 | MANDATORY APPENDICES I EXHIBITS |
99 | EXHIBIT A MAINTENANCE, TESTING, AND INSPECTION LOG – STEAM HEATING BOILERS |
101 | EXHIBIT B MAINTENANCE, TESTING, AND INSPECTION LOG – HOT WATER HEATING BOILERS |
103 | EXHIBIT C TESTS I. FLAME SAFEGUARD DEVICE A. Gas — Thermal Type B. Oil — Thermal Type, Stack Switch C. Gas — Electronic Flame Rod Type With Stand-ing Pilot D. Gas — Electronic Flame Rod With Interrupted Ignition E. Gas — Electronic Flame Scanner Type. F. Oil — Electronic Flame Scanner Type G. Oil or Gas — Electric Type With Proven Pilot Flame Detection H. Pilot Turndown Test |
104 | I. Reference to ASME CSD- 1. II. COMBUSTION EFFICIENCY TESTS A. Oil Burners B. Gas Burners |
105 | C. Draft Measurements at the Boiler Breeching. III. LIMIT CONTROL TESTS A. High- Limit Steam Pressure Control. B. Draft- Limit Control. C. Boiler Room Temperature- Limit Control. D. Electrical Limit Controls. E. Low Gas Pressure Control. F. High Gas Pressure Control. G. Oil Pressure Supervisory Switch. |
106 | H. Air Pressure Supervisory Switch. I. Emergency Disconnect Switch. IV. SAFETY VALVE TESTS (STEAM BOILERS) A. Try Lever Test. B. Pop Test. |
107 | C. Capacity Test V. SAFETY RELIEF VALVE TEST (WATER BOILERS) A. Try Lever Test B. Safety Relief Valve Test |
109 | II SUBMITTAL OF TECHNICAL INQUIRIES TO THE BOILER AND PRESSURE VESSEL COMMITTEE II- 100 INTRODUCTION II- 200 INQUIRY FORMAT II- 300 CODE REVISIONS OR ADDITIONS |
110 | II- 400 CODE CASES II- 500 CODE INTERPRETATIONS II- 600 SUBMITTALS |
112 | III STANDARD UNITS FOR USE IN EQUATIONS |
113 | NONMANDATORY APPENDIX A GUIDANCE FOR THE USE OF U. S. CUSTOMARY AND SI UNITS IN THE ASME BOILER AND PRESSURE VESSEL CODE A-1 USE OF UNITS IN EQUATIONS A-2 GUIDELINES USED TO DEVELOP SI EQUIVALENTS |
115 | A-3 SOFT CONVERSION FACTORS |
116 | INDEX |