ASHRAE Standard 22 2018
$34.13
ASHRAE Standard 22-2018 – Methods of Testing for Rating Liquid-Cooled Refrigerant Condensers
Published By | Publication Date | Number of Pages |
ASHRAE | 2018 | 20 |
ASHRAE Standard 22 prescribes methods of testing the thermal performance and liquid-side pressure drop of liquid-cooled refrigerant condensers.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | ANSI/ASHRAE Standard 22-2018 |
3 | CONTENTS |
4 | FOREWORD 1. PURPOSE 2. SCOPE 3. DEFINITIONS 4. REQUIRED TEST RESULTS 4.1 In expressing test results, the following parameters shall be stated: 4.2 For all parameters listed in Section 4.1, uncertainty shall be calculated as described in Section 7.4. 5. TEST METHODS 5.1 Standard Test Methods |
5 | 5.2 Primary Test Method FIGURE 5.1.4 Methods of producing refrigerant flow through condenser: (a) compressor and (b) boiler. FIGURE 5.2.1 Primary test method. |
6 | 5.3 Confirming Test Methods FIGURE 5.3.1 Confirming test methods. |
7 | 6. INSTRUMENTS AND TEST APPARATUS 6.1 General 6.2 Temperature-Measuring Instruments 6.3 Pressure-Measuring Instruments 6.4 Electric-Measuring Instruments 6.5 Refrigerant Flow-Measuring Instruments |
8 | 6.6 Cooling Liquid Flow-Measuring Instruments 6.7 Time Measurements. Time measurements shall be made with an apparatus whose minimum accuracy is within ±0.1% of the elapsed time. 6.8 Weight Measurements. Weight measurements shall be made with an apparatus whose minimum accuracy is within ±0.5% of the quantity measured. 7. TEST PROCEDURE 7.1 Apparatus Assembly 7.2 Operation and Limits 7.3 Computation of Results |
9 | 7.4 Uncertainty Analysis for Computed Results 8. REFERENCES |
10 | INFORMATIVE APPENDIX A—UNCERTAINTY ANALYSIS A1. Definitions A2. Methodology for Uncertainty Analysis |
11 | A3. Development of Uncertainty Calculations for Condenser Testing |
12 | A4. References |
13 | INFORMATIVE APPENDIX B—METHOD TO COMPUTE THE ENTHALPY DIFFERENCE OF A LIQUID STREAM WHEN AN EOS-BASED FUNCTION IS NOT AVAILABLE B1. Overview B2. Derivation of an Estimate for Enthalpy Difference B3. Example |
14 | B4. Recommendations B5. References FIGURE B2-1 Volume expansivity of water as reported by REFPROP. FIGURE B2-2 Relative error in heat transfer rate associated with ignoring the pressure drop of the liquid stream for water at 89.6°F (32°C). |
15 | FIGURE B3-1 Density of a 30%vol propylene glycol/water solution per Table 10 in Chapter 31 of the 2009 ASHRAE Handbook—Fundamentals (I-P). TABLE B3 Example Values for a Condenser Cooled by a Propylene Glycol Solution (Values in Bold Represent the Measurements) |
16 | FIGURE B3-2 Specific heat of a 30%vol propylene glycol/water solution per Table 11 in Chapter 31 of the 2009 ASHRAE Handbook—Fundamentals (I-P). |
17 | INFORMATIVE APPENDIX C—METHOD FOR DETERMINING THE PRESENCE OF NONCONDENSABLE GASES IN LIQUID-COOLED REFRIGERANT CONDENSERS |