ASHRAE Standard 154 2022
$54.71
ASHRAE Standard 154-2022 — Ventilation for Commercial Cooking Operations (ANSI Approved)
Published By | Publication Date | Number of Pages |
ASHRAE | 2022 |
This code-intended standard provides design criteria for commercial cooking ventilation systems. The 2022 edition harmonizes the standard with the International Mechanical Code (IMC), 2019 ASHRAE Handbook-HVAC Applications, and NFPA 96, “Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations.”
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | ANSI/ASHRAE Standard 154-2022 |
3 | Contents |
4 | Foreword 1. Purpose 2. Scope 3. Definitions |
8 | 4. Exhaust Hoods |
9 | Table 1 Type I Hood Requirements by Appliance Type |
10 | Table 2 Type II Hood Requirements by Appliance Description |
11 | Table 3 Minimum Overhang Requirements for Type II Hoods |
13 | Table 4 Type II Hood Minimum Net Exhaust Airflow Rates Figure 1 3 × 3 ft (914 × 914 mm) partial side panel. 5. Exhaust Systems |
16 | 6. Replacement Air |
17 | 7. System Controls 8. Administration And Compliance 9. References |
19 | Informative Appendix A: Examples of Air Balancing A1. Conventional Air Balancing A2. Best Practice Air Balancing A3. Pressure Differentials |
20 | Table A-1 Air Balance for Conventional Restaurant Figure A-1 Conventional restaurant air balance example. |
21 | Table A-2 Air Balance for Best Practice Restaurant Figure A-2 Best practices restaurant air balance example. |
22 | Informative Appendix B: Alternative Airflow Calculation Method B1. Exhaust Airflow Calculation B2. Thermal Plume Calculation |
23 | Table B-1 Unlisted Hood Effectiveness Values Table B-2 Reduction Factors Table B-3 Example Appliance Specifications Table B-4 Hydraulic Diameter for Each Appliance Calculated Using Equation B-3 Table B-5 Thermal Plume Airflows Calculated for Each Appliance Using Equation B-2 B3. Airflow Calculation Example |
24 | Informative Appendix C: Hood Energy Savings Calculation |
25 | Table C-1 Appendix C Nomenclature |
26 | Informative Appendix D: Using ASHRAE Standard 154 to Determine Hood Overhangs and Exhaust Airflows D1. Appliances Underneath the Hood D2. Unhooded Appliance Descriptions |
27 | Table D-1 Minimum Hood Length Table D-2 Minimum Hood Depth Table D-3 Hooded Appliance Heat Gain Estimations Table D-4 Unhooded Appliance Heat Gain Estimations |
29 | Informative Appendix E: Examples of Fan Types Used in Type 1 Exhaust Applications E1. Power Roof Ventilator E2. Tubular Centrifugal E3. Centrifugal Fan E4. High-Plume Fan |
30 | Figure E-1 (a) Power roof ventilator (upblast fan) and (b) hinged power roof ventilator (upblast fan). |
31 | Figure E-2 Tubular centrifugal (inline) fan. Figure E-3 Centrifugal fan (utility set). |
32 | Figure E-4 High-plume fan. |
33 | Informative Appendix F: Pollution Control Unit Used in Type 1 Exhaust Applications F1. Pollution Control Unit Figure F-1 Pollution control unit. |
34 | Informative Appendix G: Informative References and Bibliography |
35 | Informative Appendix H: Addenda Description Table H-1 Addenda to ANSI/ASHRAE Standard 154-2016 |