ASCE 9780784411384 2010
$107.25
Pipelines 2010
Published By | Publication Date | Number of Pages |
ASCE | 2010 | 1590 |
This collection contains 152 papers presented at the Pipelines 2010 Conference, held in Keystone, Colorado, August 28-September 1, 2010.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Cover |
6 | Table of Contents |
18 | Construction A Study on Seismic Behavior of Buried Steel Pipelines Crossing Active Faults |
30 | A Variety of Construction Methods and Pipeline Materials Help Create a New Sewer System |
40 | CSO Conveyances Project—Selection, Analysis, Design, and Specifications with Multiple Competitive Pipe Materials |
48 | Demanding HDD Installation of Fusible 24-Inch PVC Pipe Sets New Record |
58 | Design-Build of Wastewater Force Main in North Bay Village, Florida |
68 | Development and Construction of the Nation’s Largest Water Main Rehab Project |
78 | Experimental Investigation of the Effect of Microfibers on the Tensile and Flexural Strengths of Low-Viscosity Grouts |
88 | General Services Contracting for Sewer Construction |
98 | Hueneme Outfall Confronts Unique Challenges in Horizontal Directional Drilling and Marine Construction for New Ocean Outfall |
110 | Implementing an Aquifer Storage and Recovery Project |
124 | Interceptor Construction in an Urban Area—How the City of Aurora Managed Competing Interests by Considering Constructability and Routing |
137 | Joint Integrity of Plastic Pressure Pipes in Municipal Service |
148 | Lessons from an HDD Project That Was Awarded for $1.74 Million with 90 Days to Complete That Took in Excess of $6 Million and More Than 1,000 Days |
158 | Managing Challenges Building the Aurora Prairie Waters Project |
168 | New Application for Fiber Wrap Strengthening of Buried Pipelines |
177 | One Project, Four Trenchless Methods |
187 | P.I.P.E. Solutions of the South Mainland Water Transmission Main |
199 | Pipe Joint Integrity: Cementitious and Metallic Pressure Pipes |
209 | Project Management Information Systems for Pipeline Design and Construction—PrairieNet |
220 | Protecting Existing PCCP Subject to External Transient Loads |
228 | Rapid Emergency Pipeline Repairs Utilizing CFRP |
237 | Raw Sewage through Steel Pipe: A Unique Application on the Pima County Plant Interconnect |
248 | Steel Selection and Pipe Fabrication Challenges of a 120-Inch-Diameter High-Strength-Steel Tunnel Liner Project |
258 | Tunneling Saves Money and the Environment |
268 | Twenty-One Foot Diameter Flexible Pipe—Construction |
277 | Twenty-One Foot Diameter Flexible Pipe—Design |
286 | Design Preserving Capacity in CUWCD Aqueducts |
295 | Collecting and Converting 2-D Utility Mapping to 3-D |
302 | Contribution of Frictional Resistance to Restrain Unbalanced Thrust in Buried Pipelines |
312 | Design and Specification of Bolted Flange Joints in Water/Wastewater Practice |
326 | Features of the Lake Powell Pipeline Preliminary Design to Minimize Hydraulic Transients |
340 | Design of the Colorado Ocean Relief Sewer Project |
350 | Directional Drilling Design with ASTM F1962: A Decade of Success |
360 | Historic Development Adds Challenge to Storm Drain Tunnel under Railroad |
370 | Importance of Blowoffs and Design Considerations |
377 | Knoxville Utilities Board: Goose Creek Inverted Siphon Replacement |
387 | Materials Handling during Utilities Construction in Areas of Known Soil and Groundwater Contamination |
398 | Mechanical Property Changes in Steel during the Pipe Making Process |
410 | National Survey of Current Practices on Trench Bedding, Backfill, and Shoring |
419 | Performance of Plastic Pipes Installed in Dune Sand |
432 | Pipe Bursting Repair of the City of Tallahassee: Capital Circle 36-Inch Hobas Force Main |
443 | Pipe Zone Bedding And Backfill: A Flexible Pipe Perspective |
456 | Pipeline Appurtenance Alternatives |
466 | Reduction of Damage and Hindrance to Wastewater Transmission Systems Caused by Air Pockets by Deployment of Air Valves |
480 | Seismic Design of Ring Girders (1 of 2) |
489 | Seismic Design of Ring Girders Example (2 of 2) |
503 | Simplifying Upper Diamond Fork System Hydraulic Operations |
513 | Surge Control: When and Where in the Life of a Pipeline System |
525 | Thrust Induced Movement of Pipe Bends for Differing Pipe Materials |
535 | Trenchless Crossing of the South Platte River: A Case Study in Risk Management |
545 | Understanding Pipe Standard Specifications and Their Applications |
555 | Infrastructure Assessment/Monitoring 1 Advances in CCTV Technology for In-Service Water Mains |
565 | Prestressed Concrete Cylinder Pipe Decay |
575 | An Unexpected Christmas Present—Failure of a 48-Inch Waterline |
583 | Asset Management of a Failing 36″ Ductile Iron Sewage Force Main |
594 | Condition Assessment of Pressure Water Mains—Is It Worth Doing? |
608 | Considerations for Selecting Conveyance System Performance Measures |
618 | Innovative Inspection of Critical Large Diameter PCCP Pipelines without Completely De-Watering and under a River Crossing for Dallas Water Utilities |
628 | Detecting Wire Breaks from the Outside of PCCP |
637 | Establishing an Evaluation Matrix for Condition Assessment of Water Mains |
645 | Evaluating the Functionality of Water Distribution Networks in the Aftermath of Big Earthquakes Based on Nonlinear Modeling of Pipes Connections |
655 | Causes of Etiwanda Pipeline Mortar Lining Failure |
665 | Forensic Analysis of Oxidation Embrittlement in Failed HDPE Potable Water Pipes |
680 | Implementation of a Risk Based Asset Management Program: Aurora Water’s Story |
686 | Measuring the Energy Efficiency of Water Utilities |
698 | Metropolitan Water District of Southern California PCCP Condition Assessment and Comparison and Blind Test of RFTC and P-Wave |
708 | New Design Methods for Structural Rehabilitation of Rigid Pipes |
718 | PCCP Damage during Depressurization/Pressurization Cycles |
728 | Pipe Wall Evaluation Using Acoustic Pulses |
736 | Polyethylene Encasement for External Corrosion Control for Iron Pipelines—A Fifty Year History |
747 | Predictability and Preventability Indices for PCCP Water Mains |
760 | Process for Evaluating Sanitary Sewer Pipe and Manhole Condition Assessment Data |
770 | Research and Development Needs for the Inspection of Pressure Pipelines |
781 | Trenchless Water Main Rehabilitation Design Considerations |
792 | Update on the U.S.-China Collaborative Research Directions on Trenchless Technology and Critical Underground Infrastructure Issues |
810 | Use of Surface Potential and Other Electrical Measurements for Corrosion Assessments of Large Diameter Transmission Pipes |
820 | When to Intervene? Using Rates of Failure to Determine the Time to Shut Down Your PCCP Line |
832 | Infrastructure Assessment/Monitoring 2 Acoustic Based Condition Assessment of Asbestos Cement Water Transmission Laterals |
843 | Acoustic Wall Thickness Assessment of Large Diameter Mains |
853 | Alternatives for Condition Assessment of Small Diameter Sewage Force Mains |
863 | Application of Decision Support Models in Asset Management of Sewer Networks: Framework and Case Study |
874 | Classifying Structural Condition of Deteriorating Stormwater Pipes Using Support Vector Machine |
884 | Condition Assessment Methods for AC Pipe and Current Practices |
895 | Condition Assessment of 108 Miles of Water Transmission Laterals |
907 | Condition Assessment of a Pre-Stressed Concrete Cylinder Pipe While In Service |
916 | Condition Assessment of In-Service Ferous Mains |
926 | Damage Identification Based on Vibration Response of Prestressed Concrete Pipes |
937 | Detecting Deteriorating Thinning PCCP Pipe Mortar Coating |
942 | Emergency Action Plan for Failed Pipelines: A Proactive Solution |
951 | Head to Head Comparison of Large Diameter Leak Detection Methods in Denver, CO |
961 | Interactive GIS Tools for Sewer Assessment, Sewer Rehabilitation, and I/I Reduction |
971 | Laboratory Investigations of Corrosion Mechanisms and Control for Ductile Iron Pipe in Simulated Polyethylene Encasement (AWWA C105) |
996 | Large-Diameter RCP Condition Assessment Program—A Progressive Approach |
1006 | Leading the Way: The Washington Suburban Sanitary Commission’s Comprehensive PCCP Management Program |
1015 | Lessons Learned from Goleta West Rehabilitation Program |
1023 | Live Inspection of Large Diameter PCCP Using a Free-Swimming Tool |
1033 | Measurement and Analysis of PCCP Wire Breaks, Slips, and Delaminations |
1042 | Operations, Maintenance, and Capacity Improvements to the Papillion Creek Interceptor Sewer: Omaha, Nebraska |
1055 | Pipeline Case Histories with 2D and 3D Underground Imaging |
1065 | Safety and Waste Management of Asbestos Cement Pipes |
1075 | Structural Condition Assessment for Long Term Management of Critical Sewer Pipelines |
1085 | Use of Trenchless Technologies for a Comprehensive Asset Management of Culverts and Drainage Structures |
1095 | New and Emerging Technologies A Study on the Effects of Surface Transverse Waves on Buried Steel Pipelines Considering the Nonlinear Behavior of Soil and Pipes |
1105 | Advancements in FRP Repair of PCCP |
1115 | Alignment Geohazard Evaluations Using Interactive GIS |
1129 | An Assessment of the Performance of Corrugated HDPE Pipe in Shallow Fills under Railroads |
1140 | Analysis of Interaction Mechanism between Slips and Drill Rod |
1150 | Carbon Fiber Reinforced Polymer (CFRP) As a Long Term Repair Solution |
1160 | Critical Factors to Consider in Designing and Implementing Effective Carbon Fiber Repairs of Pressure Pipelines |
1167 | Emergency Repair of a Mile Long Cast in Place Reinforced Concrete Penstock Using Fiber Reinforced Polymer (FRP) Technology |
1177 | Experimental Investigation of Pipe Soil Friction Coefficients for Direct Buried PVC Pipes |
1187 | Experimental Research on Ductile Iron Pipes with Rubber Gasketed Joints |
1194 | Field Demonstration of Emerging Pipe Wall Integrity Assessment Technologies for Large Cast Iron Water Mains |
1205 | Field Demonstration of Innovative Leak Detection/Location Technologies in Conjunction with Pipe Wall Thickness Testing for Water Mains |
1216 | GIS Asset Management of New Capital Projects |
1222 | HDD Crossing of Lake Austin Generates Data and New Model for Calculating Pull Force for Ductile Iron Pipe |
1234 | Improved Flexible-Expansion Joint Design Simplifies Pipeline Protection |
1246 | Innovative Application of Leak Detection Technology on a Combined Sewer System |
1253 | Performance of 120-Inch PressureCast Steel Pipe under 120° Sand-Bearing and Installed Condition |
1261 | Lateral Loading Experiment on Buried Pipe Using Liquefied Stabilized Soil as Backfill Material for Thrust Restraint |
1272 | No-Dig Solution to Major Sewer Line in St. Louis |
1277 | Numerical Modeling of Flow around Pipeline in Currents |
1287 | Rehabilitation of High Pressure Pipelines by an Innovative New Self Monitoring Internal Reinforcement Technology |
1297 | Superlaminate: The Next Generation of Carbon FRP Products for Repair of Pipelines |
1307 | Targeted HDD Design under Critical Structures to Reduce the Potential for Hydraulic Fracture |
1317 | Testing and Evaluation of a New Potable Water Pipe Renewal Product |
1328 | The Rehabilitation of a Crude Oil Cased Crossing by the Insertion of a Self-Monitoring Layered Thermoplastic Composite Pipe with High Pressure Capability: A Case Study |
1338 | Transient Pressure Monitoring Program—Nacimiento Water Project |
1345 | Planning How Do You Spell Rehabilitation Success? — SSERP (A Program Approach to Comprehensive Wastewater Collection System Rehabilitation) |
1355 | A Successful Strategy for Environmental Permitting of an Aggressively Scheduled Major Water Supply Project |
1367 | Adfreeze Behavior between Chilled Gas Pipeline and Surrounding Frost Bulb |
1377 | Applicability of Restrained Joint PVC Pipe in Horizontal Directional Drilling |
1388 | Baton Rouge, Louisiana Sanitary Sewer Overflow Program Conveyance Design Requirements |
1398 | City of Modesto Takes a Proactive Approach to Avoid Sanitary Sewer Spill in Dry Creek: Constructing The Dry Creek/El Rio Sewer System |
1409 | Current Issues in the Trenchless Rehabilitation of Water Mains |
1418 | Design and Construction of the Lake Fork Pipeline |
1428 | Dynamic Simulation for Optimal Facility Sizing As Part of the Eastern New Mexico Rural Water Supply Project |
1438 | Emergency Assessment and Repair of a Sanitary Sewer by Trenchless and Traditional Open-Cut Methods |
1447 | Establishing an Evaluation Matrix for Water Main Rehab |
1457 | Evaluation, Inspection, and Rehabilitation of a Major Storm Sewer in the City of Aurora, Colorado |
1468 | Extending the Life of Iron Pipe in Corrosive Soils |
1478 | How Reclaimed Water Makes Cents |
1488 | Hydraulic Transient Modeling and Mitigation for a 100 Well, 146-Million-Gallon-per-Day Aquifer Storage and Recovery System |
1498 | Innovative Design of Large Diameter Fittings for the Lake Fork Interconnect Vault |
1509 | Integrated Decision-Support Framework for Municipal Infrastructure Asset |
1520 | Landfill Gas Pipeline Project Requires Aggressive Schedule to Achieve Significant Energy Savings for Milorganite Production |
1531 | Managing Project Budget Expectations through the Monitoring and Reporting of Pipeline Material Costs |
1540 | Plan, Finance, Design, and Deliver: How to Implement a Citywide Sanitary Sewer Improvement Program |
1552 | Planning, Design, and Construction of the Central Utah Water Conservancy District Water Development Project—CWP Pipeline |
1562 | Sanitary Sewer Rehabilitation Using Cured in Place Pipe (CIPP) in the City of Aurora: A Municipal Owner’s Perspective |
1571 | The Logistics of Large Diameter Waterline Shutdowns |
1581 | Understanding Your Manholes—Translating Inspection Data to Design |