AAMI 60601 2 20 2009 RA 2014 A1 2016

$131.66

ANSI/AAMI/ IEC 60601- 2-20:2009/(R)2014 & A1:2016 – Medical Electrical Equipment-Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators

Published By Publication Date Number of Pages
AAMI 2009 65
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This standard applies to the basic safety and essential performance of transport incubators. This standard does not apply to heating devices intended for physiotherapy, baby incubators, radiant warmers.

PDF Catalog

PDF Pages PDF Title
1 ANSI/AAMI/IEC 60601-2-20:2009, Medical Electrical Equipment —Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators
2 Objectives and uses of AAMI standards and recommended practices
3 Title page
4 AAMI Standard
Copyright information
5 CONTENTS
6 Glossary of equivalent standards
8 Committee representation
9 Background of ANSI/AAMI adoption of IEC 60601-2-20:2009
10 FOREWORD
12 INTRODUCTION
13 201.1 Scope, object and related standards
201.1. 1 Scope
14 201.1. 2 Object
201.1.3 *Collateral standards
201.1. 4 Particular standards
15 201.2 Normative references
201.3 Terms and definitions
18 201.4 General requirements
201.4.1 Conditions for application to ME EQUIPMENT or ME SYSTEMS
201.4.3 *Essential performance
201.4.3.101 ESSENTIAL PERFORMANCE of INFANT TRANSPORT INCUBATORS
201.4.10 Power supply
201.4.10.101 *Ability to operate with different power supply sources
19 201.4.10.102 Capacity of TRANSPORTABLE ELECTRICAL POWER SOURCE
201.4.10.103 Overcharge of TRANSPORTABLE ELECTRICAL POWER SOURCE
201.5 General requirements for testing ME EQUIPMENT
201.5.3 *Ambient temperature, humidity, atmospheric pressure
20 201.5.4 Other conditions
201.6 Classification of ME EQUIPMENT and ME SYSTEMS
201.7 ME EQUIPMENT identification, marking and documents
201.7.2 Marking on the outside of ME EQUIPMENT or ME EQUIPMENT parts
201.7.2.101 *Oxygen monitor
201.7.2.102 Heater surface temperature
201.7.4 Marking of controls and instruments
201.7.4.2 *Control devices
201.7.9.2.2 Warning and safety notices
21 201.7.9.2.8 *Start-up PROCEDURE
201.7.9.2.9 *Operating instructions
22 201.7.9.3 Technical description
201.7.9.3.1 General
201.8 Protection against electrical HAZARDS from ME EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS of ME EQUIPMENT and ME SYSTEMS

201.9.2 Hazards associated with moving parts
201.9.2.1 General
201.9.4.2.1 Instability in transport position
23 201.9.4.3 Instability from unwanted lateral movement (including sliding)
201.9.4.3.101 Tip-over force
201.9.4.3.102 *Prevention of movements
201.9.4.3.103 Prevention of infant’s movements
201.9.4.3.104 *Prevention of vibration
201.9.6.2 Acoustic energy
201.9.6.2.1 Audible acoustic energy
24 201.9.6.2.1.101 Sound level within the compartment
201.9.6.2.1.102 * Audible alarms sound level
201.9.6.2.1.103 * Audible alarms sound level within compartment
201.9.8 Hazards associated with support systems
201.9.8.3 Strength of patient or operator support or suspension systems
201.9.8.3.1 General
25 201.9.8.3.101 *Barriers
201.9.8.3.102 Mattress tray
201.9.8.101 Supports and mounting brackets for accessories
201.10 Protection against unwanted and excessive radiation HAZARDS
26 201.11 Protection against excessive temperatures and other HAZARDS
201.11.1.2.2 APPLIED PARTS not intended to supply heat to a PATIENT
201.11.2 * Fire prevention
201.11.6.2 *Overflow in ME EQUIPMENT
201.11.6.2.101 Water level indicator
201.11.6.3 *Spillage on ME EQUIPMENT and ME SYSTEMS
27 201.11.6.6 *Cleaning and disinfection of ME EQUIPMENT and ME SYSTEMS
201.11.8 Interruption of the power supply / SUPPLY MAINS to ME EQUIPMENT
201.12 Accuracy of controls and instruments and protection against hazardous outputs
201.12.1 Accuracy of controls and instruments
201.12.1.101 * Stability of TRANSPORT INCUBATOR TEMPERATURE
201.12.1.102 * Uniformity of TRANSPORT INCUBATOR TEMPERATURE
28 201.12.1.103 *Accuracy of SKIN TEMPERATURE SENSOR
201.12.1.104 *Accuracy between SKIN TEMPERATURE and CONTROL TEMPERATURE
201.12.1.105 *Accuracy of TRANSPORT INCUBATOR TEMPERATURE indication
29 201.12.1.106 *Accuracy of TRANSPORT INCUBATOR TEMPERATURE control
201.12.1.107 *Warm-up time
201.12.1.108 *Overshoot of TRANSPORT INCUBATOR TEMPERATURE
201.12.1.109 *Accuracy of indication of relative humidity
30 201.12.1.110 * Oxygen control
201.12.1.111 *Air velocity
201.12.1.113 Change in ambient temperature
31 201.12.1.114 Provision of oxygen
201.12.1.115 Overshoot of TRANSPORT INCUBATOR TEMPERATURE
201.12.1.116 * Weighing Scale
32 201.12.2 Usability
201.12.2.101 *Indication of SKIN TEMPERATURE
201.12.2.102 *Indication of the mode of operation
201.12.2.103 Temperature control
201.12.3 ALARM SYSTEMS
33 201.12.3.101 *Air circulation fan
201.12.3.102 *Connector to SKIN TEMPERATURE SENSOR
201.12.3.103 Interruption of power supply
34 201.12.3.104 AUDIO PAUSED of audible alarm
201.12.3.105 Alarm function test
201.12.4.2 Indication of parameters relevant to safety
201.12.4.2.101 *CO2-concentration
201.13 HAZARDOUS SITUATIONS and fault conditions
201.13.2.2 *Electrical SINGLE FAULT CONDITION
35 201.13.2.6 *Leakage of liquid
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.15.3 Mechanical strength
201.15.3.101 Access to the INFANT
201.15.3.4.2 *PORTABLE ME EQUIPMENT
36 201.15.4.1 Construction of connectors
201.15.4.1.101 * Connection of temperature sensors
201.15.4.2 Temperature and overload control devices
201.15.4.2.1 Application
201.15.4.2.2 *Temperature settings
37 201.15.4.6.1 Fixing, prevention of maladjustment
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS
202 Electromagnetic compatibility – Requirements and tests
202.6.2.3 Radiated RF electromagnetic fields
202.6.2.3.1 *Requirements
38 210 Requirements for the development of physiologic closed-loop controllers
210.5.1 * Instructions for use
210.5.2 Technical description
210.6.1 USABILITY
210.6.3 * PCLCS VARIABLE logging
210.8.2.2.6 *Responses of the PCLCS
Annexes
39 Annex AA (informative) Particular guidance and rationale
Subclause 201.1.3 – Collateral standards
Subclause 201.3.208 – INFANT TRANSPORT INCUBATOR
Subclause 201.4.3 – ESSENTIAL PERFORMANCE
40 Subclause 201.4.10.101 – Ability to operate with different power sources
Subclause 201.5.3 – Ambient temperature, humidity, atmospheric pressure
Subclause 201.7.2.101 – Oxygen monitor
41 Subclause 201.7.4.2 – Control devices
Subclause 201.7.9.2.2 – Warnings and safety notices
Subclause 201.7.9.2.8 – Start-up PROCEDURE
Subclause 201.7.9.2.9 – Operating instructions
Subclause 201.9.4.3.102 – Prevention of movements
Subclause 201.9.4.3.104 – Prevention of vibration
42 Subclause 201.9.6.2.1.102 – Audible alarms sound level
Subclause 201.9.6.103 – Audible alarms sound level within COMPARTMENT
Subclause 201.9.8.3.101 – Barriers
Subclause 201.11.2 – Fire prevention
43 Subclause 201.11.6.2 – Overflow in ME EQUIPMENT
Subclause 201.11.6.3 – Spillage on ME EQUIPMENT and ME SYSTEM
Subclause 201.11.6.6 – Cleaning and disinfection of ME EQUIPMENT and ME SYSTEMS
Subclause 201.12.1.101 – Stability of TRANSPORT INCUBATOR TEMPERATURE
Subclause 201.12.1.102 – Uniformity of TRANSPORT INCUBATOR TEMPERATURE
Subclause 201.12.1.103 – Accuracy of SKIN TEMPERATURE
Subclause 201.12.1.104 – Accuracy between SKIN TEMPERATURE and CONTROL TEMPERATURE
Subclause 201.12.1.105 – Accuracy of TRANSPORT INCUBATOR TEMPERATURE indication
44 Subclause 201.12.1.106 – *Accuracy of TRANSPORT INCUBATOR TEMPERATURE control
Subclause 201.12.1.107 – Warm-up time
Subclause 201.12.1.108 – Overshoot of TRANSPORT INCUBATOR TEMPERATURE
Subclause 201.12.1.109 – Accuracy of indication of relative humidity
Subclause 201.12.1.110 – Oxygen control
Subclause 201.12.1.111 – Air velocity
Subclause 201.12.1.116 – Weighing Scale
45 Subclause 201.12.2.101 – Indication of SKIN TEMPERATURE
Subclause 201.12.2.102 – Indication of the mode of operation
Subclause 201.12.3.101 – Air circulation fan
Subclause 201.12.3.102 – Connector to SKIN TEMPERATURE SENSOR
Subclause 201.12.4.2.101 – CO2-concentration
Subclause 201.13.2.2 – Electrical SINGLE FAULT CONDITION
Subclause 201.13.2.6 – Leakage of liquid
46 Subclause 201.15.3.4.2 – PORTABLE ME EQUIPMENT
Subclause 201.15.4.1.101 – Connection of temperature sensors
Subclause 201.15.4.2.2 – Temperature settings
Subclause 202.6.2.3.1 – Requirements
Subclause 210.5.1 – Instructions for use
Subclause 210.6.3 – PCLCS VARIABLE logging
47 Subclause 210.8.2.2.6 – * Responses of the PCLCS
48 Bibliography
49 Index of defined terms used in this particular standard
51 Title page
52 AAMI Standard
Copyright information
53 Contents
54 Glossary of equivalent standards
55 Committee representation
56 Background of ANSI/AAMI adoption of Amendment 1 to IEC 60601-2-20:2009
57 Foreword
59 List of amendments
AAMI 60601 2 20 2009 RA 2014 A1 2016
$131.66